Biosense Webster, Inc., a worldwide leader in the diagnosis and treatment of cardiac arrhythmias, announced that it has received approval from the United States Food and Drug Administration (FDA) for its THERMOCOOL SMARTTOUCH Catheter. This device is the first therapeutic catheter approved in the U.S. that enables direct and real-time measurement of contact force during catheter ablation procedures for patients suffering from drug-resistant paroxysmal atrial fibrillation (Afib), sustained monomorphic ischemic ventricular tachycardia and Type I atrial flutter.
Providing doctors with contact force stability when applying radiofrequency energy (RF) against the heart wall during catheter ablation has been shown to improve outcomes as inconsistent tissue contact may result in incomplete lesion formation that could result in the need for additional treatment, and too much contact may result in tissue injury, which may lead to complications. The THERMOCOOL SMARTTOUCH Catheter enhances a physician’s ability to achieve stable and consistent application of contact force by providing direct, real-time quantitative feedback graphically displayed on the company’s CARTO 3 System upon tissue contact. Without this technology, catheter tip-to-tissue contact has to be estimated through other indirect measures such as electrogram parameters and impedance but they have been shown to be poor predictors of contact force. 1
“The THERMOCOOL SMARTTOUCH Catheter is an important new device that will benefit the electrophysiology community, as it will enable us to more precisely control the amount of contact force applied to the heart wall when creating lesions during catheter ablation,” said Andrea Natale, MD, Primary Investigator of the SMART-AF Trial and Executive Medical Director of the Texas Cardiac Arrhythmia Institute at St. David’s Medical Center in Austin, TX. “Data from the SMART-AF Trial demonstrated that consistent and stable application of contact force has a significant impact on patient outcomes. The use of contact force-sensing technology has emerged as a critical tool in delivering optimal outcomes in the treatment of patients with atrial fibrillation and represents a major advancement for the clinical community.”
The safety and effectiveness of the THERMOCOOL SMARTTOUCH Catheter were evaluated as part of a prospective, multicenter study called the SMART-AF Trial in patients with drug-resistant symptomatic paroxysmal atrial fibrillation. One-year results from the trial showed that patients experienced a 74 percent overall success rate after treatment with the THERMOCOOL SMARTTOUCH Catheter. Importantly, data from the trial showed higher success rates the longer physicians stayed within a targeted contact force range, with one-year results demonstrating an 88 percent success rate when physicians stayed within a targeted range greater than or equal to 85 percent of the time. The trial demonstrated for the first time that it is the consistent and stable application of contact force on the heart wall that positively impacts the efficacy of the procedure in this patient population.
“We are pleased to be able to introduce this important advancement to help clinicians enhance the quality of care they deliver for the thousands of U.S. atrial fibrillation patients in need of alternative treatments to drug therapy,” said David Shepherd, Worldwide President of Biosense Webster. “The burden of atrial fibrillation on quality of life, morbidity and mortality is well-documented and we are committed to developing life-enhancing therapies to continue addressing unmet needs in this space.”