Medical Design and Outsourcing

  • Home
  • Medical Device Business
    • Mergers & Acquisitions
    • Financial
    • Regulatory
  • Applications
    • Cardiovascular
    • Devices
    • Imaging
    • Implantables
    • Medical Equipment
    • Orthopedic
    • Surgical
  • Technologies
    • Supplies and Components Index
    • Contract Manufacturing
    • Components
    • Electronics
    • Extrusions
    • Materials
    • Motion Control
    • Prototyping
    • Pumps
    • Tubing
  • MedTech Resources
    • Medtech Events in 2026
    • The 2026 Medtech Big 100
    • Medical Device Handbook
    • MedTech 100 Index
    • Subscribe to Print Magazine
    • DeviceTalks
    • Digital Editions
    • eBooks
    • Educational Assets
    • Manufacturer Search
    • Podcasts
    • Webinars / Digital Events
    • Whitepapers
    • Voices
    • Views
    • Video
  • 2026 Leadership
    • 2025 Winners
    • 2024 Winners
    • 2023 Winners
    • 2022 Winners
    • 2021 Winners
  • Women in Medtech
  • Advertise
  • Subscribe

Implanted Heart Device Linked to Increased Survival

June 4, 2014 By Duke Medicine

Implantable cardioverter defibrillators (ICDs) are associated with improved survival among heart failure patients whose left ventricles only pump 30 to 35 percent of blood out of the heart with each contraction, according to a study from the Duke Clinical Research Institute.Implantable cardioverter defibrillators (ICDs) are associated with improved survival among heart failure patients whose left ventricles only pump 30 to 35 percent of blood out of the heart with each contraction, according to a study from the Duke Clinical Research Institute.

The findings, published in the June 4 issue of the Journal of the American Medical Association, support existing recommendations to implant ICDs in patients with a left ventricular ejection fraction (LVEF) – a measurement of how much blood is squeezed out of the heart – of 35 percent or lower.

“Our findings fill an important gap in knowledge, as most randomized clinical trials of ICDs include heart failure patients with a median LVEF of well below 30 percent,” said Sana Al-Khatib, M.D., MHS, the study’s lead investigator and associate professor of medicine at Duke.

“Given that a large number ICDs are implanted in patients with a LVEF between 30 to 35 percent, understanding outcomes in such patients is important.”

ICDs are small devices implanted in the chest to monitor the heart’s rhythm and deliver small electrical pulses or shocks to help treat life-threatening heart rhythm disorders. Previous clinical trials have shown that ICDs are the best therapy currently available to prevent sudden cardiac death in patients with heart failure.

The researchers found that survival of heart failure patients with a LVEF of 30 to 35 percent was significantly improved in those with ICDs versus those without ICDs. Three-year mortality rates dropped from 55 percent to 51.4 percent when an ICD was implanted.

Similarly, ICDs were associated with increased survival among heart failure patients with a LVEF of less than 30 percent, with three-year mortality rates dropping from 57.6 percent to 45 percent with ICD use.

Joint guidelines from the American College of Cardiology Foundation and the American Heart Association recommend using ICDs to prevent sudden cardiac death in select patients with a LVEF of 35 percent or less. The American College of Cardiology defines a normal heart’s LVEF as 50 to 70 percent, while a measurement below 50 percent may be a sign of dysfunction or heart failure.

To better understand outcomes among heart failure patients with a LVEF of 30 to 35 percent, the researchers studied the National Cardiovascular Data Registry, intended to track primary prevention ICDs implanted in Medicare beneficiaries, making it the largest repository of ICD implants in the United States. They compared individuals in the registry with heart failure patients in the Get With the Guidelines-Heart Failure database who also had a LVEF of 30 to 35 percent but did not have ICDs.

The researchers compared all-cause mortality among those with and without ICDs, looking at a total of 3,120 patients with a LVEF of 30 to 35 percent. The analysis was repeated in 4,578 patients with a LVEF of less than 30 percent.

“Until now, the association between the ICD and improved outcomes in patients with a LVEF of 30 to 35 percent was largely implied,” Al-Khatib said. “Our results support current guidelines to implant prophylactic ICDs in patients with a LVEF of 35 percent or lower.”

In addition to Al-Khatib, Duke study authors include Anne Hellkamp, Daniel Mark, Lesley Curtis, Adrian Hernandez, Kevin Anstrom, Eric Peterson, Gillian Sanders, Hussein Al-Khalidi and Bradley Hammill. Gregg Fonarow of the University of California, Los Angeles; Paul Heidenreich of Stanford University and Palo Alto Veteran’s Health Care System; and Stephen Hammill of Mayo Clinic also contributed to the research.

The National Health, Lung, and Blood Institute funded the study (1R01-HL093071-01A1).

Related Articles Read More >

Verily Study Watch
Verily says its Study Watch could identify heart failure risk
A child using a medical device at home.
Device design takes the spotlight among 2024’s top health tech hazards
These 11 medical device inventions are the best of 2023, Time magazine says
A photo of a Best Buy Geek Squad employee helping a chronic care patient with a remote monitoring device.
Device manufacturers have an unexpected ally for at-home health care
“mdo
EXPAND YOUR KNOWLEDGE AND STAY CONNECTED
Get the latest medical device business news, application and technology trends.

DeviceTalks Weekly

See More >

MDO Digital Edition

Digital Edition

Subscribe to Medical Design & Outsourcing. Bookmark, share and interact with the leading medical design engineering magazine today.

MEDTECH 100 INDEX

Medtech 100 logo
Market Summary > Current Price
The MedTech 100 is a financial index calculated using the BIG100 companies covered in Medical Design and Outsourcing.

New MedTech Resource

Medical Tubing

MassDevice

Mass Device

The Medical Device Business Journal. MassDevice is the leading medical device news business journal telling the stories of the devices that save lives.

Visit Website
MDO ad
Medical Design and Outsourcing
  • MassDevice
  • DeviceTalks
  • MedTech100 Index
  • Medical Tubing + Extrusion
  • Medical Design Sourcing
  • Drug Delivery Business News
  • Drug Discovery & Development
  • Pharmaceutical Processing World
  • R&D World
  • About Us/Contact
  • Advertise With Us
  • Subscribe to Print Magazine
  • Subscribe to our E-Newsletter
  • Listen to our Weekly Podcasts
  • Join our DeviceTalks Tuesdays Discussion

Copyright © 2026 Arrowfly, LLC. All Rights Reserved. The material on this site may not be reproduced, distributed, transmitted, cached or otherwise used, except with the prior written permission of Arrowfly LLC. Site Map | Privacy Policy | RSS

Search Medical Design & Outsourcing

  • Home
  • Medical Device Business
    • Mergers & Acquisitions
    • Financial
    • Regulatory
  • Applications
    • Cardiovascular
    • Devices
    • Imaging
    • Implantables
    • Medical Equipment
    • Orthopedic
    • Surgical
  • Technologies
    • Supplies and Components Index
    • Contract Manufacturing
    • Components
    • Electronics
    • Extrusions
    • Materials
    • Motion Control
    • Prototyping
    • Pumps
    • Tubing
  • MedTech Resources
    • Medtech Events in 2026
    • The 2026 Medtech Big 100
    • Medical Device Handbook
    • MedTech 100 Index
    • Subscribe to Print Magazine
    • DeviceTalks
    • Digital Editions
    • eBooks
    • Educational Assets
    • Manufacturer Search
    • Podcasts
    • Webinars / Digital Events
    • Whitepapers
    • Voices
    • Views
    • Video
  • 2026 Leadership
    • 2025 Winners
    • 2024 Winners
    • 2023 Winners
    • 2022 Winners
    • 2021 Winners
  • Women in Medtech
  • Advertise
  • Subscribe