Medical Design and Outsourcing

  • Home
  • Medical Device Business
    • Mergers & Acquisitions
    • Financial
    • Regulatory
  • Applications
    • Cardiovascular
    • Devices
    • Imaging
    • Implantables
    • Medical Equipment
    • Orthopedic
    • Surgical
  • Technologies
    • Supplies and Components Index
    • Contract Manufacturing
    • Components
    • Electronics
    • Extrusions
    • Materials
    • Motion Control
    • Prototyping
    • Pumps
    • Tubing
  • MedTech Resources
    • Medtech Events in 2025
    • The 2024 Medtech Big 100
    • Medical Device Handbook
    • MedTech 100 Index
    • Subscribe to Print Magazine
    • DeviceTalks
    • Digital Editions
    • eBooks
    • Manufacturer Search
    • Podcasts
    • Print Subscription
    • Webinars / Digital Events
    • Whitepapers
    • Voices
    • Video
  • 2025 Leadership
    • 2024 Winners
    • 2023 Winners
    • 2022 Winners
    • 2021 Winners
  • Women in Medtech
  • Advertise
  • Subscribe

New Brain Mapping Tool Produces Higher Resolution Data During Brain Surgery

May 25, 2017 By University of California - San Diego

Researchers have developed a new device to map the brain during surgery and distinguish between healthy and diseased tissues. The device provides higher resolution neural readings than existing tools used in the clinic and could enable doctors to perform safer, more precise brain surgeries.

The device is an improved version of a clinical tool called an electrode grid, which is a plastic or silicone-based grid of electrodes that is placed directly on the surface of the brain during surgery to monitor the activity of large groups of neurons. Neurosurgeons use electrode grids to identify which areas of the brain are diseased in order to avoid damaging or removing healthy, functional tissue during operations. Despite their wide use, electrode grids have remained bulky and have not experienced any major advances over the last 20 years.

The PEDOT:PSS electrode grid is a new brain mapping device that can be used during brain surgery. (Credit: David Baillot/UC San Diego Jacobs School of Engineering)

The new electrode grid, developed by a team of researchers at the University of California San Diego and Massachusetts General Hospital, is about a thousand times thinner — six micrometers versus several millimeters thick — than clinical electrode grids. This allows it to conform better to the intricately curved surface of the brain and obtain better readings. The new electrode grid also contains a much higher density of electrodes — spaced 25 times closer than those in clinical electrode grids — enabling it to generate higher resolution recordings.

“Our goal is to develop a tool that can obtain more reliable information from the surface of the brain,” says electrical engineering professor Shadi Dayeh, who co-led the study with neuroscience professor Eric Halgren and electrical engineering professor Vikash Gilja, all at UC San Diego. The project was funded by the Center for Brain Activity Mapping (CBAM) at UC San Diego and brought together experts from multiple fields, including neurosurgeons, neuroscientists, electrical engineers, materials scientists and experts in systems integration. Researchers published their work on May 12 in Advanced Functional Materials.

“By providing higher resolution views of the human brain, this technology can improve clinical practices and could lead to high performance brain machine interfaces,” Gilja says.

To make their high resolution electrode grid, researchers had to find a way to shrink the size of the electrodes to pack them closer together. But with metal electrodes, which are typically used to make these grids, there is a tradeoff — shrinking their size increases their electrical resistance, resulting in more noisy readings.

To overcome this problem, the team switched out the metal electrodes with ones made of a conductive polymer called PEDOT:PSS. The material is transparent, thin and flexible. Using this material enabled researchers to make smaller electrodes without sacrificing electrochemical performance. It also enhanced the richness of the information measured from the surface of the brain.

“These electrodes occupy minuscule volumes — imagine Saran wrap, but thinner. And we demonstrate that they can capture neural activity from the human brain at least as well as conventional electrodes that are orders of magnitude larger,” Gilja says.

Researchers worked with neurosurgeons at Thornton Hospital at UC San Diego and Brigham Women’s Hospital in Boston to test their grid on four patients. The PEDOT:PSS electrode grid and a standard clinical electrode grid were compared side by side. In standard clinical recordings, the PEDOT:PSS electrode grid either performed similarly or slightly better than the standard electrode grid, recording with lower noise and higher resolution.

“In order to introduce a new electrode grid for clinical use, we first need to show that the device can yield the same information as that used in the clinic. Then we can build upon that work to make an even better product that can improve patient care,” Dayeh says.

In one test, the team performed background readings of a patient’s brain waves both while the patient was awake and unconscious. The PEDOT:PSS electrode grid produced similar readings as the standard clinical electrode grid. In another test, the team monitored the brain activity of a patient undergoing epilepsy surgery. Both electrode grids identified normal functioning areas of the brain versus where the seizures were happening. The main difference is that the PEDOT:PSS electrode grid produced more detailed and higher resolution readings than the clinical electrode grid.

Other tests monitored the brain activity of patients performing cognitive tasks. Patients were either shown a particular word or a picture illustrating that word. The word was afterwards recited to the patients. In the readings from both the PEDOT:PSS and standard electrode grids, researchers could differentiate between when the patients were hearing the word versus when they were seeing it (or a picture). “This experiment shows we can resolve functional and cognitive activity from the surface of the brain using these electrodes,” Dayeh says.

The team’s next steps are to make higher density electrode grids for improved resolution and biocompatibility tests to see how long they can stay in the body before they experience biofouling.

Related Articles Read More >

A photo of the miniature Auxilium Biotechnologies implants made on the International Space Station.
Implants 3D-printed in space could enable nerve regeneration
An illustration showing the Artedrone Sasha thrombectomy catheter approaching a blood clot.
This microrobot system is designed to float inside a stroke patient for autonomous thrombectomy
A photo of nitinol, a nickel-titanium alloy used for medical devices such as stents, heart valves, catheters and orthopedics.
What is nitinol and where is it used?
An image of Abbott's Infinity deep brain stimulation (DBS) implants and leads.
How Abbott developed the first-of-its-kind Infinity DBS system
“mdo
EXPAND YOUR KNOWLEDGE AND STAY CONNECTED
Get the latest medical device business news, application and technology trends.

DeviceTalks Weekly

See More >

MDO Digital Edition

Digital Edition

Subscribe to Medical Design & Outsourcing. Bookmark, share and interact with the leading medical design engineering magazine today.

MEDTECH 100 INDEX

Medtech 100 logo
Market Summary > Current Price
The MedTech 100 is a financial index calculated using the BIG100 companies covered in Medical Design and Outsourcing.
DeviceTalks

DeviceTalks is a conversation among medical technology leaders. It's events, podcasts, webinars and one-on-one exchanges of ideas & insights.

DeviceTalks

New MedTech Resource

Medical Tubing

MassDevice

Mass Device

The Medical Device Business Journal. MassDevice is the leading medical device news business journal telling the stories of the devices that save lives.

Visit Website
MDO ad
Medical Design and Outsourcing
  • MassDevice
  • DeviceTalks
  • MedTech100 Index
  • Medical Tubing + Extrusion
  • Medical Design Sourcing
  • Drug Delivery Business News
  • Drug Discovery & Development
  • Pharmaceutical Processing World
  • R&D World
  • About Us/Contact
  • Advertise With Us
  • Subscribe to Print Magazine
  • Subscribe to our E-Newsletter
  • Listen to our Weekly Podcasts
  • Join our DeviceTalks Tuesdays Discussion

Copyright © 2025 WTWH Media, LLC. All Rights Reserved. The material on this site may not be reproduced, distributed, transmitted, cached or otherwise used, except with the prior written permission of WTWH Media LLC. Site Map | Privacy Policy | RSS

Search Medical Design & Outsourcing

  • Home
  • Medical Device Business
    • Mergers & Acquisitions
    • Financial
    • Regulatory
  • Applications
    • Cardiovascular
    • Devices
    • Imaging
    • Implantables
    • Medical Equipment
    • Orthopedic
    • Surgical
  • Technologies
    • Supplies and Components Index
    • Contract Manufacturing
    • Components
    • Electronics
    • Extrusions
    • Materials
    • Motion Control
    • Prototyping
    • Pumps
    • Tubing
  • MedTech Resources
    • Medtech Events in 2025
    • The 2024 Medtech Big 100
    • Medical Device Handbook
    • MedTech 100 Index
    • Subscribe to Print Magazine
    • DeviceTalks
    • Digital Editions
    • eBooks
    • Manufacturer Search
    • Podcasts
    • Print Subscription
    • Webinars / Digital Events
    • Whitepapers
    • Voices
    • Video
  • 2025 Leadership
    • 2024 Winners
    • 2023 Winners
    • 2022 Winners
    • 2021 Winners
  • Women in Medtech
  • Advertise
  • Subscribe