Medical Design and Outsourcing

  • Home
  • Medical Device Business
    • Mergers & Acquisitions
    • Financial
    • Regulatory
  • Applications
    • Cardiovascular
    • Devices
    • Imaging
    • Implantables
    • Medical Equipment
    • Orthopedic
    • Surgical
  • Technologies
    • Supplies and Components Index
    • Contract Manufacturing
    • Components
    • Electronics
    • Extrusions
    • Materials
    • Motion Control
    • Prototyping
    • Pumps
    • Tubing
  • MedTech Resources
    • Medtech Events in 2026
    • The 2026 Medtech Big 100
    • Medical Device Handbook
    • MedTech 100 Index
    • Subscribe to Print Magazine
    • DeviceTalks
    • Digital Editions
    • eBooks
    • Educational Assets
    • Manufacturer Search
    • Podcasts
    • Webinars / Digital Events
    • Whitepapers
    • Voices
    • Views
    • Video
  • 2026 Leadership
    • 2025 Winners
    • 2024 Winners
    • 2023 Winners
    • 2022 Winners
    • 2021 Winners
  • Women in Medtech
  • Advertisers
    • Advertise
    • PR Submissions
    • Eblast Submissions
  • Subscribe

Using CT, radiologists can pinpoint cause of some strokes

November 8, 2010 By EurekAlert

OAK BROOK, Ill. Multidetector computed tomography (CT) helps pinpoint the causes of ischemic strokes, the most common type of stroke, potentially speeding the delivery of life-saving treatments, according to a study published online and in the January issue of Radiology.

“Our results suggest that multidetector CT could become the first-line imaging tool for identifying the cause of acute ischemic stroke,” said the study’s lead author, Loic Boussel, M.D., Ph.D., professor of radiology at Louis Pradel Hospital in Bron, France.

An ischemic stroke occurs when blockage in an artery, often from a blood clot or a fatty deposit due to atherosclerosis, interrupts blood flow to an area of the brain. This type of stroke can originate in the heart, in the form of a blood clot that travels to the head, or from blood vessels in the neck (extracranial carotid arteries) and head (intracranial arteries). According to the American Stroke Association, ischemic stroke accounts for approximately 87 percent of stroke cases.

Early determination of the cause of ischemic stroke is essential for secondary stroke prevention. Anticoagulant therapy to thin the blood is the treatment of choice for most of the cardiac sources of stroke, while surgery is needed for strokes caused by severe narrowing of the extracranial carotid artery.

Physicians use a combined imaging protocol to determine the cause of an ischemic stroke. The protocol typically includes duplex ultrasonography, MR angiography or CT angiography of the neck and brain vessels, and transthoracic and transesophageal echocardiography.

“This approach is time-consuming and expensive, and could delay secondary stroke prevention strategies,” Dr. Boussel said.

In the new study, Dr. Boussel and colleagues analyzed the potential of multidetector CT as a faster and more cost-effective way to detect the main causes of ischemic stroke. The researchers compared a single-session multidetector CT examination of the heart, neck and brain vessels with established imaging methods in 46 patients who had recently experienced an ischemic stroke.

Almost half of the stroke cases had cardiac sources, while 20 percent of cases were caused by major arterial atherosclerosis.

Multidetector CT detected cardiac sources of stroke in 18 of 25 cases, for a sensitivity of 72 percent. The technique’s sensitivity increased to 100 percent for detection of major arterial atherosclerosis. Overall, multidetector CT facilitated stroke classification in 38 of the 46 patients, or 83 percent.

“CT allows a fast diagnosis and helps to identify the cause of the stroke during a single examination,” Dr. Boussel said. “Moreover, because it is quick, the exam is well tolerated, which is critical in acute stroke patients who may be unstable and agitated.”

The CT protocol has two main limitations, according to Dr. Boussel. It exposes the patient to a significant radiation dose and requires two intravenous contrast material injections to study the chest and neck areas. Dr. Boussel said that advances in CT equipment technology could help reduce the radiation dose and the total amount of iodinated contrast material required.

Larger studies are needed to validate the results and to analyze the technique’s cost-effectiveness.

SOURCE

Related Articles Read More >

An illustration showing the Autus size-adjustable heart valve being expanded years after implantation with a minimally invasive balloon catheter.
The first-of-its-kind Autus pediatric heart valve is designed for expansion and durability
The MIT researcher's implant, LUCID.
MIT researchers design implantable ultrasound-powered drug delivery device to minimize tumor recurrence
An image of the Teleflex Freesolve RMS resorbable magnesium scaffold.
Teleflex Interventional leader sees resorbables as ‘the next frontier’ of PCI
Feminai's breast sensor patch
AdvaMed and MedTech Innovator name 2026 prize winners and finalists
“mdo
EXPAND YOUR KNOWLEDGE AND STAY CONNECTED
Get the latest medical device business news, application and technology trends.

DeviceTalks Weekly

See More >

MDO Digital Edition

Digital Edition

Subscribe to Medical Design & Outsourcing. Bookmark, share and interact with the leading medical design engineering magazine today.

MEDTECH 100 INDEX

Medtech 100 logo
Market Summary > Current Price
The MedTech 100 is a financial index calculated using the BIG100 companies covered in Medical Design and Outsourcing.

New MedTech Resource

Medical Tubing

MassDevice

Mass Device

The Medical Device Business Journal. MassDevice is the leading medical device news business journal telling the stories of the devices that save lives.

Visit Website
MDO ad
Medical Design and Outsourcing
  • MassDevice
  • DeviceTalks
  • MedTech100 Index
  • Medical Tubing + Extrusion
  • Medical Design Sourcing
  • Drug Delivery Business News
  • Drug Discovery & Development
  • Pharmaceutical Processing World
  • R&D World
  • About Us/Contact
  • Advertise With Us
  • Subscribe to Print Magazine
  • Subscribe to our E-Newsletter
  • Listen to our Weekly Podcasts
  • Join our DeviceTalks Tuesdays Discussion

Copyright © 2026 Arrowfly, LLC. All Rights Reserved. The material on this site may not be reproduced, distributed, transmitted, cached or otherwise used, except with the prior written permission of Arrowfly LLC. Site Map | Privacy Policy | RSS

Search Medical Design & Outsourcing

  • Home
  • Medical Device Business
    • Mergers & Acquisitions
    • Financial
    • Regulatory
  • Applications
    • Cardiovascular
    • Devices
    • Imaging
    • Implantables
    • Medical Equipment
    • Orthopedic
    • Surgical
  • Technologies
    • Supplies and Components Index
    • Contract Manufacturing
    • Components
    • Electronics
    • Extrusions
    • Materials
    • Motion Control
    • Prototyping
    • Pumps
    • Tubing
  • MedTech Resources
    • Medtech Events in 2026
    • The 2026 Medtech Big 100
    • Medical Device Handbook
    • MedTech 100 Index
    • Subscribe to Print Magazine
    • DeviceTalks
    • Digital Editions
    • eBooks
    • Educational Assets
    • Manufacturer Search
    • Podcasts
    • Webinars / Digital Events
    • Whitepapers
    • Voices
    • Views
    • Video
  • 2026 Leadership
    • 2025 Winners
    • 2024 Winners
    • 2023 Winners
    • 2022 Winners
    • 2021 Winners
  • Women in Medtech
  • Advertisers
    • Advertise
    • PR Submissions
    • Eblast Submissions
  • Subscribe